Paint Meter Calibration

Paint Meter Calibration

 

Coating Thickness Gauge calibration procedure

Calibration Plate can be also used to validate the operation of the meter.

Coating thickness gauge P-11-S-AL

After applied probe to the plate "FE-200um" paint meter should show 200 um +/- 10um.


Beware! Paint meters without the possibility of measurement on aluminum car body elements are only included a single steel plate with "FE-200um" description.
Calibration plate for Aluminium with "AL-200um" description is included only for paint meters which can measures on aluminum.



Calibration procedure for A-10-FE seriers:

In the case of wrong measurement results device should be calibrate. For this please use attached grey calibration plate with FE-200um description.
When the paint meter is off please press and hold the
Coating Thickness Gauge calibration button for 10 seconds. On the display shows the sequence numbers 90, 80, 70, 60, 50, 40, 30, 20, 10 and the message "HL" "FE" - now release the Coating Thickness Gauge calibration button. Applied the probe to calibration plate with FE-200um description and press Coating Thickness Gauge calibration. Now the meter is calibrated and you are ready to take measurements.


Calibration procedure for MGR-10 and P-10 seriers:


In the case of wrong measurement results device should be calibrate. For this please use attached grey calibration plate with FE-200um description and eventually (only if device can measure on aluminium) red calibration plate with AL-200um description
When the paint meter is off please press and hold green "ON" and red "OFF" (approx. two seconds) until you see the message "CALIBR". When the message "AL-200um" show on the display, please applied the probe to the calibration plate and press the blue button with "Memory" description (approx. 1 second).
When the message "FE-200um", t
show on the display, please applied the probe to the calibration plate and press the blue button with "Memory" description (approx. 1 second).

After this, the device is calibrated.



Calibration procedure for MGR-11 and P-11 seriers:

In the case of wrong measurement results device should be calibrate. For this please use attached grey calibration plate with FE-200um description and eventually (only if device can measure on aluminium) red calibration plate with AL-200um description
When the device is switched on, please press and hold 
Coating Thickness Gauge calibration KAL button for approx. 5 seconds until the display shows the sequence number of 80, 70, 60, 50, 40, 30, 20, 10 and the message "HL".

When you see the message "AL", please applied probe to the red calibration plate with "AL-200um" description and press Coating Thickness Gauge calibration . When you see the message "FE" on the display, please applied probe to the grey calibration plate with "FE-200um" description and press Coating Thickness Gauge calibration .